Hitachi Aloka ARIETTA 70 Ultrasound System with SOFIA'S Convertible Table and High Density Transducers
Hitachi Aloka ARIETTA 70 Ultrasound System with SOFIA'S Convertible Table and High Density Transducers
$100,095 (USD)
Available quantity:1
Description
Hitachi Aloka ARIETTA 70 Ultrasound System with SOFIA'S Convertible Table and High Density Transducers
- CONDITION: Pre-owned. These units have been used at a local doctors office a handful of times. The condition of all the items is used but they are in excellent condition. The units come as pictured. Each component has been fully tested and inspected for proper use. There are no tears, rips. cuts or scratches on the table. The Hitachi Aloka ARIETTA 70 portable system shows normal signs of cosmetic wear and use. This is the same for the transducers that are included.
- DESCRIPTION OF INCLUDED ITEMS:
- HITACHI ARIETTA 70 Ultrasound Monitoring/Mobile Workstation: SN- 20684719
-POWER REQUIREMENTS
Input: 240/120 V @ 60 Hz
Power Consumption:(Standard Components):580 VA(With Optional Recorders):900 VA
-SYMPHONIC TECHNOLOGY: Arietta 70’s Symphonic Technology optimizes
data fidelity along the entire signal handling chain.
-Multi-layered Crystal: Multiple crystal layers within each element, minimize
signal attenuation.
-Compound Pulse Wave Generator: Unique transmission technology reduces heat
generation, allowing stronger pulses to improve SNR.
-Pixel Focusing: Dynamically focusing at the pixel level improves resolution and
image uniformity.
-Ultra Backend: High-speed digital computing fuels real- time image processing features.
-IPS-Pro Display Monitor: Delivers wide half-contrast viewing angle and excellent
contrast, black levels, and switching speed.
-Physical Dimensions: Weight: 258 lbs. (117 kg);
Dimensions: 21”(W) x 31”(D) x 51-69”(H) Display: 21” IPS Pro
-SUPPORTED DICOM OPTIONS
DICOM Store (Storage Commit) DICOM Print
DICOM Query/Retrieve
DICOM Modality Worklist
-HI Definition Tissue Harmonic Imaging (HdTHI): Extends penetration and increases
resolution by transmitting a wide band pulse and receiving the second harmonic
and sub-harmonic signals across the entire spectrum of the probe bandwidth.
-HI Compound Imaging (HI Com): Is especially beneficial for improving the visibility of
luminal structures. HI Com transmits and receives ultrasound beams in various
directions and superimposes the resultant images in real time.
-Adaptive Imaging (HI REZ+): Utilizes Hitachi Aloka’s high speed digital processing engine to
extract structures and emphasize tissues without reducing frame rate.
-Fine Flow: Displays high-definition, high frame rate color Doppler images of fine vessels with
minimal blooming.
- HITACHI SOFIA Examination Table: SN-20180305
-Length: 77” (195.58 cm)
-Width: 32” (81.28 cm)
-Height: 25”-37” (63.5-93.98 cm) Weight: 450 lbs. (204 kg)
-Max. Weight Rating: 300 lbs. (136 kg)
-Minimum Room Requirements: 10' Wide x 6' Long; door to enter exam room must be 34"
-SCANNING METHODS
Automatic Image Acquisition
Manual Image Acquisition (Table Transducer)
Manual Image Acquisition (Manual Transducer)
-ELECTRICAL POWER – EXAMINATION ROOM
Voltage: 120 V AC
Max Amperage: 10 AMP
Frequency: 50/60 Hz
Continuous Power: Not Required
Max. Receptacle Distance: 72” (183 cm)
-ELECTRICAL POWER – REVIEW WORKSTATION
Voltage: 100-230 V AC
Max Amperage: 5.3 AMP
Frequency: 50/60 Hz
Continuous Power: Not Required
Max. Receptacle Distance: 72” (183 cm)
-COMPUTER NETWORK/ PACS/TELERAD
Computer Storage Space: 1GB
Max. Outlet Distance: 60” (153 cm)
Minimum Upload Speed: 3 MB/sec
-REVIEW WORKSTATION
Processor: Intel i7
Memory: 8 GB
Hard Drive: 1 TB
Graphics Card: High Performance Monitor: 2 Megapixel
- C251 High Density Transducer with Smart Connectors:
-Abdominal Imaging and Biopsy 5-1 MHz ⎮75° (50mmR)
- C41V1 High Density Transducer with Smart Connectors:
-Endocavity 10-2 MHz⎮200° (10 mmR)
- L55 High Density Transducer with Smart Connectors:
-Breast, Small Parts, Thyroid 13-5MHz ⎮50 mm
- Power Requirements
-Input: 240/120 V @ 60 Hz
-Power Consumption: (Standard Components): 580 VA (With Optional Recorders): 900 VA
YEAR MANUFACTURED:
SHIPPING: PLEASE CONTACT FOR A FREIGHT QUOTE
WE STRIVE FOR 100% CUSTOMER SATISFACTION. CONTACT US IMMEDIATELY IF THERE IS ANYTHING THAT WOULD PREVEN YOU FROM GIVING US AN EXCEPTIONAL RATING!
WARRANTY/RETURNS:
-No warranty is expressed or implied with the sale of this item(s).
-Buyer has 30 days to return or exchange (if inventory allows) the product(s). Buyer is responsible for all and any shipping costs/fees.
ADDITIONAL COMMENTS:
-Concern or query: Ask a Question (email or call anytime)
-If item is expired it is offered for training or demo use ONLY- (offered AS IS)
-Accessories: Items come as described and the listing description will provide any additional components.
DISCLAIMERS:
This item is Being Sold in AS IS condition & the seller assumes no responsibility for the proper or improper use of the product. If the item is to be used in conjunction with patient care and/or diagnosis, it is responsibility of the buyer to get proper certifications/licenses for the use of the item. It would be highly recommended and wise to have a bio-med completely check the product for its performance and safety parameters before actual use for patient care and/or diagnosis. Seller disclaims any obligation, responsibility, or liability, which concerns or relates to any information, product or services and is not liable for any direct or indirect claim, loss or damage resulting from use of this product, web page and/or any web site(s) linked to/from it.
Regardless of the origin of the products, documentation provided or identification appearing upon the items, the items described and offered here are in no way certified for, recommended for, or offered for any specific use. We are not responsible for the misuse, intentional or accidental, of any item purchased through our listing style, fixed priced, or Store Inventory listings. It is the purchaser's sole responsibility to follow and adhere to all manufacturer's guidelines and instructions for proper use of said item. If you are not licensed to purchase a regulated item, then please do not bid on that item or use the Buy it Now feature if offered.
The sale of this item may be subject by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
Specifications
Manufacturer | HITACHI |
Model | ARIETTA 70. SOFIA. C251. L55. C41V1. AR70. |
Condition | Used |
Serial Number | 20684719:AR70; TABLE:SOFIA: 20180305-00082 |
Brand | HITACHI |
Manufacture | HITACHI |
REFERENCE | ARIETTA 70.SOFIA. C251. L55. C41V1. AR70. |
Model | ARIETTA 70. SOFIA. C251. L55. C41V1. AR70. |
Intended use/discipline | RADIOLOGY. INTERVENTIONAL RADIOLOGY. OBSTETRICS. ABDOMINAL. PERIPHERAL VASCULAR. UROLOGY. MUSCULOSKELETAL.PEDIATRICS. CARDIOLOGY |
Description | HITACHI.X-RAY.OB/GYN. MEDICAL.OB/GYN.GYNECOLOGY. X-RAY. PATIENT MONITORING.DISPLAY MONITOR. TRANSDUCERS.COMPUTER.WORKSTATION.PORTABLE. |
Est. shipping(us) | CONTACT FOR QUOTE |